Related Experiment Video
Updated: Aug 11, 2025

Severe Burn Injury in a Swine Model for Clinical Dressing Assessment
Published on: November 6, 2018
The potential fire risk of emollients when dried on viscose bandages
Roisin McDermott1, Lucy Taylor2, Nicola Housam3
1Research Assistant, Leicester Institute of Pharmaceutical Innovation, De Montfort University, Leicester.
Background:
the potential fire risk of fabrics impregnated with emollients has been described within the health service, including ignition of bandages. The role of emollients in fire fatalities have also been included in coroner reports, as accelerating fires when present.
Aims:
although changes in burning behaviour is known, no standard tests have been carried out on bandages which are often used in conjunction with emollients.
Method:
using a standard vertical flammability test, the flammability of viscose bandage was compared to when impregnated with nine dried on emollients with low to high and non-paraffin content.
Findings:
the time to ignition was significantly reduced with an emollient present and the glowing time was longer.
Conclusions:
the same safety advice applies to viscose bandages as other fabrics with emollients; do not expose them to naked flames or high heat sources or allow emollients to build up on bandages.
Related Concept Videos
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
PPE Use in Healthcare Settings II: Doffing
Decreased Body Temperature
Hand hygiene
Hand washing...
PPE Use in Healthcare Settings I: Donning
Characteristics of Dry Friction
Before the wheelbarrow starts moving, the static frictional force acts tangentially to the contact surface, opposing the force that is about to induce the motion. This frictional force prevents the...