Performance of portable objective wound assessment tools: a systematic review
Related Experiment Video
Updated: Aug 11, 2025

Digital Planimetry for Assessing Wound Closure Kinetics in a Mouse Model
Published on: January 10, 2025
Poh Tan1,2, Razan A Basonbul3, Joanne Lim4
1Burns and Plastics Department, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Medical Centre, Birmingham, UK.
Objective:
Accurate wound assessment is crucial for determining the progression of healing and guides treatment strategies. Portable wound assessment devices can be useful in providing an accurate evaluation in the community where most cases are treated. The objective of this review was to compare the performance of various portable wound assessment techniques used for wound healing assessment described in the literature.
Method:
In April 2020, electronic databases were searched, using appropriate search terms, for all available publications on the use of portable wound assessment devices on human and artificial wounds. The primary outcome was the reliability and reproducibility of measurement while the secondary outcome was the feasibility of the instrument. All studies underwent quality assessment of diagnostic accuracy studies (QUADAS) to examine the quality of data.
Results:
A total of 129 articles were identified and 24 were included in the final review; 17 articles discussed two-dimensional (2D) devices; three articles discussed three-dimensional (3D) devices; and four articles discussed application-based devices. Most studies (n=8) reported on a 2D device that had an ICC of 0.92-0.99 for area measurement and a coefficient of variance of 3.1% with an error of 2.3% in human wounds and 1.55-3.7% in artificial wounds. The inter/intra observer reliability was 0.998 and 0.985, respectively with a scan time of two minutes per wound. The median QUADAS score was 12.
Conclusion:
Based on the presented evidence, 2D-based portable wound assessment devices were the most studied and demonstrated good performance. Further studies are required for 3D and application-based measurement instruments.
More Related Videos
06:45Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Published on: May 2, 2025
09:06Assessment of Acute Wound Healing using the Dorsal Subcutaneous Polyvinyl Alcohol Sponge Implantation and Excisional Tail Skin Wound Models.
Published on: March 25, 2020
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: