Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Complementary Effect of the Proportion of Overspeed Frames of Withdrawal and Withdrawal Time on Reflecting
Rongrong Gong1,2,3, Liwen Yao1,2,3, Lihui Zhang1,2,3
1Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China.
Introduction:
Constructing quality indicators that reflect the defect of colonoscopy operation for quality audit and feedback is very important. Previously, we have established a real-time withdrawal speed monitoring system to control withdrawal speed below the safe speed. We aimed to explore the relationship between the proportion of overspeed frames (POF) of withdrawal and the adenoma detection rate (ADR) and to conjointly analyze the influence of POF and withdrawal time on ADR to evaluate the feasibility of POF combined with withdrawal time as a quality control indicator.
Methods:
The POF was defined as the proportion of frames with instantaneous speed ≥44 in the whole colonoscopy video. First, we developed a system for the POF of withdrawal based on a perceptual hashing algorithm. Next, we retrospectively collected 1,804 colonoscopy videos to explore the relationship between POF and ADR. According to withdrawal time and POF cutoff, we conducted a complementary analysis on the effects of POF and withdrawal time on ADR.
Results:
There was an inverse correlation between the POF and ADR (Pearson correlation coefficient -0.836). When withdrawal time was >6 minutes, the ADR of the POF ≤10% was significantly higher than that of POF >10% (25.30% vs 16.50%; odds ratio 0.463, 95% confidence interval 0.296-0.724, P < 0.01). When the POF was ≤10%, the ADR of withdrawal time >6 minutes was higher than that of withdrawal time ≤6 minutes (25.30% vs 21.14%; odds ratio 0.877, 95% confidence interval 0.667-1.153, P = 0.35).
Discussion:
The POF was strongly correlated with ADR. The combined assessment of the POF and withdrawal time has profound significance for colonoscopy quality control.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...