Related Experiment Video
Updated: Aug 11, 2025

Author Spotlight: Advancing Pathogen Detection and Disease Assessment in Real-Time Using M-ROSE
Published on: March 1, 2024
Multiple-site decontamination in mechanically ventilated ICU patients: A real-life study
Nicolas Massart1, Clarisse Dupin2, Eleonore Legris3
1Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France.
Introduction:
Decontamination regimen decreases acquired infection (ICU-AI) incidence but has remained controversial, mostly because it contains a course of intravenous antibiotic. Multiple-site decontamination (MSD), which does not include systemic antibiotics, has been less widely studied but is associated with lower risks of ventilator-associated pneumonia (VAP), bloodstream infection (BSI) and multidrug resistant micro-organism (MDRO) acquisition. We aimed to confirm these favorable outcomes.
Methods:
A prospective pre/post-observational study was conducted in 5 ICUs in western France. Among them, 4 implemented MSD, whereas the fifth applied standard care (SC) throughout the study period. Patients who required intubation were eligible for study and divided into two groups: the MSD group if they were admitted to an ICU that already implemented MSD, or the SC group. The primary objective was to measure ICU-AI incidence.
Results:
Close to 1400 (1346) patients were available for analysis (334 in the MSD and 1012 patients in the SC group). In a multivariable Poisson regression model, MSD was independently associated with decreased incidence of ICU-AI (IRR = 0.33; 95 %CI [0.18-0.60] p < 0.001). Non-parsimonious propensity-score matching resulted in 334 patient-pairs with well-balanced baseline characteristics. There was a lower incidence of ICU-AI(6.3 % vs 20.7 % p < 0.001), VAP (3.6 % vs 16.2 % p < 0.001) and BSI (3.0 % vs 7.2 % p = 0.029) in the MSD group as compared with the SC group. Five (1.5 %) and 11 (3.3 %) patients respectively acquired MDRO (p = 0.206).
Conclusion:
MSD is associated with decreased risk of ICU-AI, VAP and BSI, with no increase in MDRO acquisition.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
04:32Murine Oropharyngeal Aspiration Model of Ventilator-associated and Hospital-acquired Bacterial Pneumonia
Published on: June 28, 2018
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: