Related Experiment Video
Updated: Aug 11, 2025

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
Human amniotic membrane graft for refractory macular hole: A single-arm meta-analysis and systematic review
Hengdi Zhang1, Y Li2, G Chen3
1Ophthalmology Department, The General Hospital of Western Theater Command, PLA, 610083 Chengdu, Sichuan Province, P.R.China.
Purpose:
The treatment of refractory macular holes is controversial, with human amniotic membrane grafts emerging recently as an attractive option. We performed a meta-analysis and systematic review in this paper to assess the results of human amniotic membrane (hAM) in the treatment of refractory macular hole (MH).
Methods:
We searched the Cochrane Database of Systematic Reviews, Web of Science, PubMed, Embase, China National Knowledge Infrastructure databases, VIP database, Wanfang Data Knowledge Service Platform, Sinomed, Chinese Clinical Trial Registry, and Clinical Trials.gov. Studies reporting hAM for the treatment of refractory MH were included. The outcomes are MH closure rate, visual acuity (VA) improvement rate, and graft dislocation/contracture rate.
Results:
A total of 8 studies on 103 eyes were included, all of which had undergone failed vitrectomy and internal limiting membrane (ILM) peeling. In all studies, the VA improvement rate was 66% (95%CI: 45 to 84%), the MH closure rate was 94% (95%CI: 84 to 100%) and the hAM graft dislocation/contracture rate was 6% (95%CI: 0 to 15%). In the studies using cryopreserved hAM grafts, the MH closure rate was 99% (95%CI: 94 to 100%) and the hAM graft dislocation/contracture rate was 3% (0%, 10%). The VA improvement rates were 94% (95%CI: 79 to 100%) in the retinal detachment subgroup, 37% (95%CI: 20 to 56%) in the pathologic myopia subgroup, and 62% (95%CI: 14 to 100%) in the idiopathic MH subgroup.
Conclusion:
Human amniotic membrane in the treatment of refractory MH results in visual improvement. It has a high macular hole closure rate and low dislocation/contracture rate. Cryopreserved hAM grafts might have better outcomes than dehydrated grafts.