Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
An improved Chemcatcher-based method for the integrative passive sampling of 44 hydrophilic micropollutants in
Vick Glanzmann1, Naomi Reymond1, Céline Weyermann1
1School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland.
Abstract:
When monitoring water quality with hydrophilic integrative passive sampling devices, it is crucial to use accurate sampling rates (RS) that account for exposure conditions such as hydrodynamics. This study aims at calibrating Chemcatcher-like passive samplers - styrene-divinylbenzene reverse phase sulfonate (SDB-RPS) extraction disk covered by a polyethersulfone (PES) membrane - at four water flow velocities (5 to 40 cm s-1) in a channel system. First, the four hydrodynamic conditions were characterized by measuring the mass transfer coefficients of the water boundary layer (kw) at the surface of the samplers using the alabaster dissolution method. Then, fifty-six samplers were deployed in the channels and exposed for 7 different intervals varying from 1 to 21 days. Thus, RS were determined at four different kw for 44 hydrophilic compounds, ranging from 0.015 to 0.115 L day-1. Relationships were established between kw and RS using models for mixed rate control by the membrane and the water boundary layer. The estimated parameters of those relationships are suitable for the determination of accurate RS when kw is measured in situ, for example by co-deploying silicone disks spiked with performance and reference compounds (PRC) as implemented in Part B.