Related Experiment Video
Updated: Aug 11, 2025

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Model-informed precision dosing of teicoplanin for the rapid achievement of the target area under the
Kazutaka Oda1,2, Tomoyuki Yamada3, Kazuaki Matsumoto4
1Department of Pharmacy, Kumamoto University Hospital, Chuo-ku, Kumamoto, Japan.
Abstract:
Teicoplanin, a glycopeptide antimicrobial, is recommended for therapeutic drug monitoring, but it remains unclear how to target the area under the concentration-time curve (AUC). This simulation study purposed to demonstrate the potential of the Bayesian forecasting approach for the rapid achievement of the target AUC for teicoplanin. We generated concordant and discordant virtual populations against a Japanese population pharmacokinetic model. The predictive performance of the Bayesian posterior AUC in limited sampling on the first day against the reference AUC was evaluated as an acceptable target AUC ratio within the range of 0.8-1.2. In the concordant population, the probability for the maximum a priori or Bayesian posterior AUC on the first day (AUC0-24 ) was 61.3% or more than 77.0%, respectively. The Bayesian posterior AUC on the second day (AUC24-48 ) was more than 75.1%. In the discordant population, the probability for the maximum a priori or Bayesian posterior AUC0-24 was 15.5% or 11.7-80.7%, respectively. The probability for the maximum a priori or Bayesian posterior AUC24-48 was 23.4%, 30.2-82.1%. The AUC at steady-state (AUCSS ) was correlated with trough concentration at steady-state, with a coefficient of determination of 0.930; the coefficients on days 7 and 4 were 0.442 and 0.125, respectively. In conclusion, this study demonstrated that early sampling could improve the probability of AUC0-24 and AUC24-48 but did not adequately predict AUCSS . Further studies are necessary to apply early sampling-based model-informed precision dosing in the clinical settings.
Related Concept Videos
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...