Full Evaporative Vacuum Extraction─A Quantitative and Green Approach for Analysis of Semivolatile Organic Compounds
1Entech Instruments Inc, 2207 Agate Ct, Simi Valley, California, 93065, United States.
Abstract:
Full evaporative vacuum extraction (FEVE) was developed in this work for analysis of a broad range of semivolatile organic compounds (SVOCs) in drinking water and surface water. Sorbent pens are used in a two-stage process that first evaporates the sample matrix through sorbent beds under vacuum to recover the lighter SVOCs, followed by the application of a higher temperature and stronger vacuum to the sample vial to recover the remaining heavier SVOCs once the matrix has evaporated. After extraction, the sorbent pens are desorbed into a GC-MS using a uniquely designed "splitless" delivery system to maximize sensitivity. Critical extraction and desorption parameters that affect the method performance were optimized. After FEVE, the sorbent pens can be stored for 7-10 days at room temperature while maintaining a less than 15% loss in analyte recovery. As a proof of concept, 10 drinking water and surface water samples were analyzed using this method. 69 analytes were detected in these water samples, with the highest concentration of 1986 ng/L for bromacil. Heptachlor epoxide, chlorpyrifos, metolachlor, butachlor, and 2,3',4',5-tetrachlorobiphenyl were detected in four samples. None of the analytes were above the health and safety thresholds set by California Proposition 65.
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Volatilization
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...