Static and Dynamic Stabilization of the Shoulder After Total Scapulectomy in an Electric Burn Patient
Jessica M May1, Abraham Pathak2, William F Pientka3
1From the Department of Plastic Surgery, University of Texas Southwestern Medical Center, Dallas, TX.
Abstract:
An otherwise healthy 49-year-old man experienced a high-voltage electrical injury to the left shoulder resulting in total scapulectomy, partial calviculectomy, and a substantial soft tissue defect. The majority of the muscles around his shoulder were debrided because of necrosis, with only the pectoralis and latissimus dorsi muscles remaining attached to the humerus. Surprisingly, the patient's brachial plexus remained intact, and his left elbow, wrist, and hand function were preserved. A novel combination of 3 static and dynamic suspension techniques were used to stabilize his shoulder and prevent traction injury to the brachial plexus. Postoperative follow-up at 1 year demonstrated excellent stability of his reconstructed shoulder, which allowed him to ambulate independently and return to employment.