Related Experiment Video
Updated: Aug 11, 2025

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
A novel external/internal tumor tracking approach to compensate for respiratory motion baseline drifts
Marta K Giżyńska1, Yvette Seppenwoolde1, Warren Kilby2
1Department of Radiotherapy, Erasmus MC Cancer Institute, Erasmus University Medical Center Rotterdam, Rotterdam, The Netherlands.
Abstract:
Objective.Real-time respiratory tumor tracking as implemented in a robotic treatment unit is based on continuous optical measurement of the position of external markers and a correlation model between them and internal target positions, which are established with X-ray imaging of the tumor, or fiducials placed in or around the tumor. Correlation models are created with fifteen simultaneously measured external/internal marker position pairs divided over the respiratory cycle. Every 45-150 s, the correlation model is updated by replacing the three first acquired data pairs with three new pairs. Tracking simulations for >120.000 computer-generated respiratory tracks demonstrated that this tracking approach resulted in relevant inaccuracies in internal target position predictions, especially in case of presence of respiratory motion baseline drifts.Approach.To better cope with drifts, we introduced a novel correlation model with an explicit time dependence, and we proposed to replace the currently applied linear-motion tracking (LMT) by mixed-model tracking (MMT). In MMT, the linear correlation model is extended with an explicit time dependence in case of a detected baseline drift. MMT prediction accuracies were then established for the same >120.000 computer-generated patients as used for LMT.Main results.For 150 s update intervals, MMT outperformed LMT in internal target position prediction accuracy for 93.7 ∣ 97.2% of patients with 0.25 ∣ 0.5 mm min-1linear respiratory motion baseline drifts with similar numbers of X-ray images and similar treatment times. For the upper 25% of patients, mean 3D internal target position prediction errors reduced by 0.7 ∣ 1.8 mm, while near maximum reductions (upper 10% of patients) were 0.9 ∣ 2.0 mm.Significance.For equal numbers of acquired X-ray images, MMT greatly improved tracking accuracy compared to LMT, especially in the presence of baseline drifts. Even with almost 50% less acquired X-ray images, MMT still outperformed LMT in internal target position prediction accuracy.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Neural Control of Respiration
Respiratory Centers in the Brainstem
Two primary areas comprise the respiratory center: the medullary respiratory center in the medulla oblongata and the pontine respiratory group in the pons. The...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...