Related Experiment Video
Updated: Aug 11, 2025

Quantitation of Intra-peritoneal Ovarian Cancer Metastasis
Published on: July 18, 2016
Initial Experience with the Radiotracer 18F-Fluciclovine PET/CT in Ovarian Cancer
Tina M Buehner1,2, Margaret Liotta3, Ronald K Potkul3
1Rush University Medical Center, Chicago, IL, USA. Tina_buehner@rush.edu.
Objective:
Early and accurate staging of ovarian cancer is paramount to disease survival. Conventional imaging including FDG PET/CT are limited in the evaluation of small metastatic lesions. 18F-Fluciclovine has minimal urine and bowel excretion allowing optimal visualization of the abdomen and pelvis. This study examines 18F-fluciclovine uptake in known primary and recurrent ovarian cancer.
Methods:
Seven patients with a confirmed diagnosis of epithelial ovarian cancer underwent 18F-fluciclovine PET/CT imaging. Forty-one (41) lesions were identified with 18F-fluciclovine and confirmed to be true positive (n = 41). We aim to explore if 18F-fluciclovine uptake in ovarian lesions were greater than background uptake of bone marrow, blood pool, and bladder. Quantification analysis was performed to determine max and mean standard uptake values (SUVmax and SUVmean) of known and suspected lesions compared to SUVmean uptake of background structures.
Results:
18F-Fluciclovine demonstrated 100% sensitivity (41/41) for uptake in known ovarian lesions. The average SUVmax (±SD) uptake of known ovarian lesions was 5.9 (±2.6) and 5.1 (±2.0) on early and delayed images, respectively. The average tumor SUVmax to SUVmean of background (±SD) (T:B) ratios on early and delay were 1.9 (±0.8), 2.1 (±0.9) for marrow; 3.8 (±1.8), 3.4 (±1.5) for aorta; and 8.4 (±4.3), 1.5 (±1.7) for bladder, respectively.
Conclusion:
18F-Fluciclovine uptake in malignant ovarian lesions was above background levels suggesting its feasibility in the imaging of ovarian cancer. Due to increasing tracer washout via the urinary bladder over time, early imaging at 4 min post injection is favorable.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...