Related Experiment Video
Updated: Aug 11, 2025

07:47
The Rodent Psychomotor Vigilance Test rPVT: A Method for Assessing Neurobehavioral Performance in Rats and Mice
Published on: December 29, 2016
12.2K
A Cross-sectional Survey on Rodent Environmental Health Monitoring Practices: Benchmarking, Associations, and
Kerith R Luchins1, Kate V Gates2, Caroline B Winn3
1Animal Resources Center and Department of Surgery, University of Chicago, Chicago, Illinois.
Summary
Environmental Health Monitoring (EHM) offers a viable alternative to traditional rodent health monitoring, yet its adoption remains low. This study surveyed professionals, revealing that positive attitudes and knowledge are key drivers for increased EHM implementation.
Area of Science:
- Laboratory animal science
- Animal welfare
- Research methodology
Background:
- Tens of thousands of rodents are utilized annually for Rodent Health Monitoring (RHM).
- Environmental Health Monitoring (EHM) presents a potential replacement for sentinel rodents, offering comparable or improved diagnostic quality.
- Despite EHM's advantages, its widespread implementation in research settings is notably limited.
Purpose of the Study:
- To investigate the current prevalence of EHM in research institutions.
- To identify factors influencing the adoption and implementation of EHM.
- To test hypotheses that EHM prevalence is low and associated with user beliefs and knowledge.
Main Methods:
- A mixed-methods survey was administered to 158 research animal professionals.
- Data collection included current practices, beliefs, and knowledge regarding EHM.
- Qualitative data underwent thematic analysis, and quantitative data were analyzed using generalized linear models.
Main Results:
- Only 11% of surveyed institutions exclusively use EHM, with over 20,000 sentinel rodents still employed annually.
- A majority (78%) of participants recognized EHM's advantage in replacing sentinel animals.
- Barriers to EHM adoption include perceived difficulty with caging types (40%), cost concerns (21%), accuracy doubts (16%), and personnel factors (14%).
Conclusions:
- Low EHM implementation necessitates targeted communication emphasizing its compatibility, cost-effectiveness, accuracy, and alignment with the 3Rs.
- Promoting EHM requires addressing user attitudes, fostering peer support, and providing implementation resources.
- Increased EHM use could significantly reduce the reliance on sentinel rodents, aligning with ethical research principles.

