Measuring Arterial Oxygen Saturation Using Wearable Devices Under Varying Conditions
Abstract:
INTRODUCTION: Recently developed wearable monitoring devices can provide arterial oxygen saturation (Spo₂) measurements, offering potential for use in aerospace operations. Pilots and passengers are already using these technologies, but their performance has not yet been established under conditions experienced in the flight environment such as environmental hypoxia and concurrent body motion.METHODS: An initial evaluation was conducted in 10 healthy subjects who were studied in a normobaric chamber during normoxia and at a simulated altitude of 15,000 ft (4572 m; 11.8% oxygen). Spo₂ was measured simultaneously using a standard pulse oximeter and four wearable devices: Apple Watch Series 6; Garmin Fēnix 6 watch; Cosinusso Two in-ear sensor; and Oxitone 1000M wrist-worn pulse oximeter. Measurements were made while stationary at rest, during very slight body motion (induced by very low intensity cycling at 30 W on an ergometer), and during moderate body motion (induced by moderate intensity cycling at 150 W).RESULTS: Missed readings, defined as failure to record an Spo₂ value within 1 min, occurred commonly with all wearables. Even with only very slight body motion, most devices missed most readings (range of 12-82% missed readings) and the rate was higher with greater body motion (range 18-92%). One device tended to under-report Spo₂, while the other devices tended to over-report Spo₂. Performance decreased across the devices when oxygenation was reduced.DISCUSSION: In this preliminary evaluation, the wearable devices studied did not perform to the same standard as a traditional pulse oximeter. These limitations may restrict their utility in flight and require further investigation.Hearn EL, Byford J, Wolfe C, Agyei C, Hodkinson PD, Pollock RD, Smith TG.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure