Related Experiment Video
Updated: Aug 11, 2025

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Studying effective column lengths in liquid chromatography of large biomolecules
Szabolcs Fekete1, Matthew Lauber2
1Waters Corporation, located in CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
Abstract:
Based on their nature, large molecules tend to exhibit on-off elution such that only a small segment of a column bed participates in their separation. We were intrigued to investigate empirical data on this behavior and to apply a simple method to estimate the length of column bed that is needed to produce an effective separation. Models were derived by rearranging the linear solvent strength (LSS) model equations, and data sets from almost 100 different separation conditions were treated to illustrate effects for various types of solutes as separated by reversed phase (RP), ion-pair reversed phase (IP-RP), ion-exchange (IEX), hydrophobic interaction (HIC) and hydrophilic interaction (HILIC) chromatography. By empirically measuring S parameters (S is a solute dependent model parameter, it describes how sensitive is the solute retention to mobile phase composition), and calculating for an exit retention factor of 0.5, we have determined that there is little to no benefit to separating moderately sized solutes (5 - 10 kDa) with a column bed that is longer than 3 cm, particularly when a less than 20 min gradient is desired. Moreover, even shorter columns would be predicted to be adequate for 100 - 150 kDa molecules. Interpretations of this sort have become possible because there is some correlation between a solute's molecular weight and its S parameter. That is, empirical observations on retention behavior are not needed to select appropriate column lengths; molecular weight provides a sufficient approximation. With these insights, we suggest reconsidering the routine use of 5 - 15 cm long columns for >10 kDa biomolecule separations and instead propose that a new focus be placed on 1-2 cm long columns.
Related Concept Videos
Principles Of Column Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...