Related Experiment Video
Updated: Aug 11, 2025

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Complications, Implant Survivorships, and Functional Outcomes of Conversion Total Knee Arthroplasty With Prior
Rit Apinyankul1, Alexander Y Hui2, Katherine Hwang2
1Department of Orthopaedics, Khon Kaen University, Khon Kaen, Thailand.
Background:
End-stage knee osteoarthritis with retained periarticular hardware is a frequent scenario. Conversion total knee arthroplasty (TKA) leads to excellent outcomes, but poses unique challenges. The evidence supporting retention versus removal of hardware during TKA is controversial.
Methods:
Patients who underwent TKA with prior hardware between January 2009 and December 2019 were identified. A total of 148 patients underwent TKA with prior hardware. The mean follow-up was 60 months (range, 24-223). Univariate and multivariable analyses were used to study correlations among factors and surgical-related complications, prosthesis failures, and functional outcomes.
Results:
The complication rate was 28 of 148 (18.9%). The use of a quadriceps snips in addition to a medial parapatellar arthrotomy was associated with a higher complication (odds ratio: 20.7, P < .05), implant failures (odds ratio: 13.9, P < .05), and lower the Veterans Rand 12 Mental Score (VR-12 MS) (-14.8, P < .05). Hardware removal versus retention and use of single versus multiple incisions were not associated with complications or prosthesis failures. Removal of all hardware was associated with significantly higher (+7.3, P < .05) VR-12 MS compared to retention of all hardware.
Conclusions:
TKA with prior hardware was associated with more complications, implant failures, and lower VR-12 MS when a more constrained construct or quadriceps snip was performed. This probably reflects the level of difficulty of the procedure rather than the surgical approach used. Hardware removal or retention was not associated with complications or implant failures; however, removal rather than retention of all prior hardware is associated with increased general health outcomes.
Level Of Evidence:
IV, cohort without control.