Related Experiment Video
Updated: Jul 13, 2026

A Modified Heterotopic Swine Hind Limb Transplant Model for Translational Vascularized Composite Allotransplantation (VCA) Research
Published on: October 14, 2013
Axillary artery to iliac vein vascular access using an externally supported prosthetic graft. A new procedure for the
G E Cimochowski1, H R Harter, W E Rutherford
1Department of Cardiac Surgery, St. Francis Medical Center, Monroe, LA.
Abstract:
The axillary artery-iliac vein graft using externally supported PTFE is a viable option for this difficult patient group. It is capable of functioning well for up to 12 months. Most importantly, despite numerous prior access procedures, the axillary artery and iliac vein in each case were amenable to the procedure. Critical technical points include the use of externally splinted PTFE grafts, avoidance of crossing joints, and angling of the graft in the direction of the iliac vein at that anastomosis. The lack of thrombosis or infection to date, coupled with successful dialysis in every patient, suggests that this is one more option that can be used in the difficult secondary access patient.