Related Experiment Video
Updated: Aug 11, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Transcutaneous carbon dioxide monitoring during prolonged apnoea with high-flow nasal oxygen
Pernille Pape1, Zofia M Piosik1,2, Camilla M Kristensen1
1Department of Anaesthesia, Centre of Head and Orthopaedics, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
Background:
The duration of apnoeic oxygenation with high-flow nasal oxygen is limited by hypercapnia and acidosis and monitoring of arterial carbon dioxide level is therefore essential. We have performed a study in patients undergoing prolonged apnoeic oxygenation where we monitored the progressive hypercapnia with transcutaneous carbon dioxide. In this paper, we compared the transcutaneous carbon dioxide level with arterial carbon dioxide tension.
Methods:
This is a secondary publication based on data from a study exploring the limits of apnoeic oxygenation. We compared transcutaneous carbon dioxide monitoring with arterial carbon dioxide tension using Bland-Altman analyses in anaesthetised and paralysed patients undergoing prolonged apnoeic oxygenation until a predefined limit of pH 7.15 or PCO2 of 12 kPa was reached.
Results:
We included 35 patients with a median apnoea duration of 25 min. Mean pH was 7.14 and mean arterial carbon dioxide tension was 11.2 kPa at the termination of apnoeic oxygenation. Transcutaneous carbon dioxide monitoring initially slightly underestimated the arterial tension but at carbon dioxide levels above 10 kPa it overestimated the value. Bias ranged from -0.55 to 0.81 kPa with limits of agreement between -1.25 and 2.11 kPa.
Conclusion:
Transcutaneous carbon dioxide monitoring provided a clinically acceptable substitute for arterial blood gases but as hypercapnia developed to considerable levels, we observed overestimation at high carbon dioxide tensions in patients undergoing apnoeic oxygenation with high-flow nasal oxygen.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-III
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...