Two-Year Outcomes of Ultrasound Cyclo Plasty as a First Procedure in Glaucoma
Faisal A Almobarak1,2, Ahmed Alrubean1,3, Waleed K Alsarhani1,4,5
1Department of Ophthalmology, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
Purpose:
To evaluate the 2-year outcomes of ultrasound cyclo plasty (UCP) as a first procedure in glaucoma.
Methods:
This retrospective cohort study included patients with uncontrolled glaucoma who underwent UCP as an initial glaucoma procedure. The main outcome measures were intraocular pressure (IOP), the number of antiglaucoma medications, visual acuity, and the presence of vision-threatening complications. Surgical outcomes of each eye were classified as either complete success, qualified success, or failure based on the main outcome measures. Differences in IOP control and success rates were compared in eyes with primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG).
Results:
We included 98 eyes of 88 patients in the study. The mean follow-up period was 27.25 ± 10.1 months. At 12 and 24 months, mean IOP decreased significantly from 23.16 ± 6.4 mmHg to 16.57 ± 6.0 mmHg and 16.18 ± 5.2 mmHg, respectively, and the number of antiglaucoma medications decreased from 3.27 ± 0.9 to 1.86 ± 1.4 and 1.70 ± 1.7, respectively (p < .01 for all). There were no changes in visual acuity throughout the follow-up compared with preoperative levels. The cumulative probabilities of success were 64.3% (±4.8) [78.9% (±9.4) complete success, and 72.9% (±6.4) qualified success], and 42.9% (±5.0) [52.6% (±11.5) complete success, and 56.3% (±7.2) qualified success] at 12 and 24 months, respectively. The most common complications were cataract development/progression, anterior chamber inflammation, and macular edema. There were no significant differences in IOP, number of antiglaucoma medications, or survival rates between POAG and PACG groups.
Conclusions:
UCP can be used as an initial glaucoma procedure for reducing IOP and the number of antiglaucoma medications and offers comparable outcomes in POAG and PACG.
More Related Videos
10:10Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents
Published on: February 15, 2022
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview