Feasibility of Dynamic Inhaled Gas MRI-Based Measurements Using Acceleration Combined with the Stretched Exponential
Ramanpreet Sembhi1, Tuneesh Ranota2, Matthew Fox1,3
1Department of Physics and Astronomy, The University of Western Ontario, London, ON N6A 3K7, Canada.
Abstract:
Dynamic inhaled gas (3He/129Xe/19F) MRI permits the acquisition of regional fractional-ventilation which is useful for detecting gas-trapping in lung-diseases such as lung fibrosis and COPD. Deninger's approach used for analyzing the wash-out data can be substituted with the stretched-exponential-model (SEM) because signal-intensity is attenuated as a function of wash-out-breath in 19F lung imaging. Thirteen normal-rats were studied using 3He/129Xe and 19F MRI and the ventilation measurements were performed using two 3T clinical-scanners. Two Cartesian-sampling-schemes (Fast-Gradient-Recalled-Echo/X-Centric) were used to test the proposed method. The fully sampled dynamic wash-out images were retrospectively under-sampled (acceleration-factors (AF) of 10/14) using a varying-sampling-pattern in the wash-out direction. Mean fractional-ventilation maps using Deninger's and SEM-based approaches were generated. The mean fractional-ventilation-values generated for the fully sampled k-space case using the Deninger method were not significantly different from other fractional-ventilation-values generated for the non-accelerated/accelerated data using both Deninger and SEM methods (p > 0.05 for all cases/gases). We demonstrated the feasibility of the SEM-based approach using retrospective under-sampling, mimicking AF = 10/14 in a small-animal-cohort from the previously reported dynamic-lung studies. A pixel-by-pixel comparison of the Deninger-derived and SEM-derived fractional-ventilation-estimates obtained for AF = 10/14 (≤16% difference) has confirmed that even at AF = 14, the accuracy of the estimates is high enough to consider this method for prospective measurements.