Related Experiment Video
Updated: Aug 10, 2025

Ultrasound Velocity Measurement in a Liquid Metal Electrode
Published on: August 5, 2015
Investigating Ultrasonic Pulse Velocity Method for Evaluating High-Temperature Properties of Non-Sintered
Wonchang Kim1, Hyeonggil Choi2, Taegyu Lee1
1Department of Fire and Disaster Prevention, Semyung University, Choongbuk 27136, Republic of Korea.
Abstract:
Research on alternative cement materials is active worldwide, and in terms of fire safety, research on the evaluation of high-temperature properties of alternative materials is very important. Studies on concrete mixed with hwangto have been conducted by several researchers, but studies on high-temperature properties are lacking. Therefore, in this study, we evaluated the mechanical properties of concrete by partially replacing cement with non-sintered hwangto (NSH) at high temperatures. Normal concrete without NSH mixing and non-sintered hwangto concrete (NSHC) with HNT replacement were prepared as the specimens. The W/B of the concrete was set to 41 and 33, whereas the NSH replacement ratio was 15 and 30% of the cement. The target heating temperatures were set to 20, 100, 200, 300, 500, and 700 °C, and the heating rate was maintained at 1 °C/min. The following were calculated to evaluate the mechanical properties of the specimens: mass loss, compressive strength, ultrasonic pulse velocity (UPV), and modulus of elasticity. After analyzing the correlation between residual compressive strength and UPV, we proposed a compressive strength prediction model using different values of W/B for NSHC. Experimental results suggest that mass loss (%) shows a decreasing trend as NSH increases. In terms of residual compressive strength, residual compressive strength at W/B 41 increased with NSH replacement, whereas residual compressive strength values for W/B 33 were observed regardless of NSH replacement. Residual UPV showed a similar trend, regardless of the NSH replacement ratio, and residual modulus of elasticity was low at all W/B ratios as NSH replacement increased. A linear equation with a high correlation coefficient (R2) was proposed to predict compressive strength, and the linear value of W/B 41 was slightly higher than that of W/B 33.
More Related Videos
09:46Protocol for Measuring the Thermal Properties of a Supercooled Synthetic Sand-water-gas-methane Hydrate Sample
Published on: March 21, 2016
10:52Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot Heater System
Published on: August 7, 2018
Related Concept Videos
Design Example: Managing Concrete Workability
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Testing Water Quality
Measurement of Air Content in Concrete
The pressure method,...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...