Related Experiment Video
Updated: Aug 10, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Compression Behavior of Concrete Columns Strengthened with Fiber-Reinforced Inorganic Composites Based on Magnesium
Qihang Zhang1, Xin Zhang1,2,3, Qiaoling Liu1,2,3
1School of Civil Engineering, Shandong Jianzhu University, Jinan 250101, China.
Abstract:
Fiber-reinforced polymer (FRP) composites have become attractive for strengthening and repairing deteriorated concrete structures. However, their poor high-temperature resistance and durability in some extreme environments, such as frequent water-vapor erosion and temperature changes, limit their application. Magnesium phosphate cement (MPC) has been used to repair damaged concrete due to its excellent high-temperature resistance and durability. Therefore, this paper aims to study the compressive behavior of concrete columns strengthened with fiber-reinforced inorganic polymer (FRiP) composites based on magnesium phosphate cement so as to evaluate the confinement effect. Twenty-one cylindrical specimens were prepared to examine the axial compressive behavior of carbon-fiber-reinforced inorganic polymer (CFRiP) specimens based on magnesium phosphate cement confined by one to three layers of carbon-fiber fabrics. They are compared with concrete specimens strengthened with epoxy-based FRP and unconfined concrete specimens. The test results show that compared with the unconfined concrete specimen, the strength of the CFRiP-strengthened specimens based on magnesium phosphate increases by 1.69-2.50 times, and their ultimate strain is enlarged by 1.83-3.50 times. The strength and ultimate strain of the CFRiP-strengthened specimens based on magnesium phosphate are approximately 95% and 60% of those of the specimens strengthened with epoxy-based FRP, respectively. A semiempirical model of concrete confined by the CFRiP system based on magnesium phosphate cement is also proposed. The theoretical prediction is finally compared with the experimental results, indicating that the developed model provides a prediction close to the test results.
Related Concept Videos
Fiber Reinforced Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Reinforcements in Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Additives and Fillers in Concrete
The...
Prestressed Concrete