A Study on the Increase of Leakage Current in AlGaN Detectors with Increasing Al Composition
Yujie Huang1,2, Jing Yang1, Degang Zhao1,3
1State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.
Abstract:
The dark leakage current of AlxGa1-xN Schottky barrier detectors with different Al contents is investigated. It was found that the dark leakage of AlxGa1-xN detectors increased with increasing Al content. The XRD and SIMS results showed that there was no significant difference of the dislocation density and carbon impurity concentration in five AlxGa1-xN samples with different Al content. This was likely not the main reason for the difference in dark leakage current of AlxGa1-xN detectors. However, the results of positron annihilation showed that the vacancy defect concentration increased with increasing Al content. This was consistent with the result that the dark leakage current increased with increasing Al content. With the increase of vacancy concentration, the vacancy defect energy levels also increased, and the probability of electron tunneling through defect levels increased. In contrast, the Schottky barrier height decreased, which eventually led to the increase of dark leakage current. This discovery should be beneficial to an accurate control of the performance of AlxGa1-xN detectors.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Diode: Reverse bias
Biasing of Metal-Semiconductor Junctions
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
Carrier Generation and Recombination
This process is given by the generation rate G and is efficient due to the conservation of momentum between the valence band maximum and conduction band minimum.
Indirect generation involves an...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...