Related Experiment Video
Updated: Aug 10, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Study on Shear Behaviors and Damage Assessment of Circular Concrete Short Columns Reinforced with GFRP Bars and
Xiaolu Wang1,2, Lingzhu Zhou1,2, Yuke Liang1,3
1School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan 523808, China.
Abstract:
This study investigated the shear resistance and damage evolution of glass fiber-reinforced polymer (GFRP)-reinforced concrete short columns. Five circular concrete short columns reinforced with GFRP bars and spiral stirrups were fabricated and tested under lateral thrust in the laboratory. The test variables involved the stirrup reinforcement ratio, the longitudinal reinforcement ratio and the type of stirrups. The failure modes, load-displacement curves, strain responses and crack characteristics of these columns were documented and discussed. The accuracy of shear design equations in predicting shear capacity of such columns was evaluated. In addition, the digital image correlation (DIC) instrument was used to identify the full-field strain and damage zones of circular concrete short columns. Several smart aggregate (SA) transducers coupled to the surface of these columns were used to monitor its damage status. The energy ratio index (ERI) and the damage index based on smart aggregate were established to characterize damage level of such columns. The test results indicate that the shear capacity is improved 5.6% and 31.1% and the lateral ultimate displacement is increased 67.7% and 400% as the stirrup reinforcement ratio of the concrete short column is increased from 0 to 0.19% and 0.47%, respectively. The shear capacity equation proposed by Ali and his co-workers, considering a strain limit of 0.004Efv, gives accurate predictions of the shear capacity of circular concrete short columns reinforced with GFRP bars and spiral stirrups. The variation in ERI values is explained by the development of damage zones of the column obtained with DIC technology and with the proposed damage index based on the smart aggregate it is feasible to evaluate the damage level of circular short concrete columns.
More Related Videos
Related Concept Videos
Reinforcements in Concrete
Design of Columns under an Eccentric Load
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Fiber Reinforced Concrete
Design Example: Distributing Reinforcements in Concrete Sections
Torsion of Noncircular Members

