Advanced Energy Management Strategy of Photovoltaic/PEMFC/Lithium-Ion Batteries/Supercapacitors Hybrid Renewable

Hesham Alhumade1,2,3, Hegazy Rezk4,5, Mohamed Louzazni6

  • 1Chemical and Materials Engineering Department, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia.

Related Concept Videos

Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
254
Conservation of AC Power01:15

Conservation of AC Power

The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
368
Energy Line and Hydraulic Gradient Line01:27

Energy Line and Hydraulic Gradient Line

Based on Bernoulli's equation, the energy line (EL) and hydraulic grade line (HGL) provide graphical representations of energy distribution in a fluid flow system. For steady, incompressible, inviscid flows, Bernoulli's equation is expressed as:
1.3K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
927
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
237
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
299