Ophthalmic viscoelastics commonly used in cataract surgery: A microbiota investigation
Kourtney K Dowler1, Aida Vientós-Plotts1, Elizabeth A Giuliano1
1Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, Missouri, USA.
Purpose:
To survey commonly used, sterile ophthalmic viscoelastic materials used during routine cataract surgery for the presence of bacterial DNA and/or viable bacteria and endotoxin quantification.
Methods:
Samples from three different ophthalmic viscoelastic manufacturers and three different production lots per manufacturer were collected for 16 S ribosomal ribonucleic acid (rRNA) sequencing and conventional aerobic and capnophilic bacterial culture. Other samples of viscoelastic material from the same three manufacturers were collected for endotoxin quantification using a commercially available Limulus amebocyte lysate (LAL) assay. Statistical analysis was performed using Sigma Plot 14.0, and R v4.0.2.0. Differences (p ≤ .05) between sample collection sites in total DNA concentration, microbial richness, mean intra-group distances, and endotoxin quantification alongside reagent controls were evaluated.
Results:
Culture yielded two isolates, identified as Staphylococcus epidermidis and Bacillus megaterium. 16 S rRNA sequencing revealed no differences between brands in richness or overall composition. The most common bacterial DNA detected across all brands was Staphylococcus sp., Cutibacterium sp., Flavobacterium sp., and Lactobacillus sp. A significant difference was found between the median endotoxin concentration between Anvision and Hyvisc® viscoelastic (Anvision: 0.171 EU/mL, Hyvisc®: 0.03 EU/mL; p < .001).
Conclusions:
No brand-specific differences in bacterial DNA were detected in the viscoelastic materials. Staphylococcus, Cutibacterium, Flavobacterium, and Lactobacillus were the dominant contributors to the bacterial DNA detected. Although Anvision viscoelastic samples contained significantly more endotoxin than Hyvisc® viscoelastic samples, endotoxin concentrations were below the FDA limit of 0.2 EU/mL for both manufacturers. These data further the understanding of inflammatory outcomes following cataract surgery.