Mengsha Zou1, Qin Zhou1, Ruocheng Li1
1Department of Radiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, PR China.
Background:
Synthetic magnetic resonance imaging (MRI) might replace the conventional MR sequences in brain evaluation to shorten scan time and obtain multiple quantitative parameters.
Purpose:
To evaluate the image quality of multiple-delay-multiple-echo (MDME) sequence-derived synthetic brain MR images compared to conventional images by considering a multi-age sample.
Material And Methods:
Image sets of conventional and synthetic MRI of 200 participants were included. On the basis of the presence of intracranial lesions, the participants were divided into a normal group and a pathological group. Two neuroradiologists compared the anonymous and unordered images. Image quality, artifacts, and diagnostic performance were analyzed.
Results:
In the quantitative analysis, comparing with conventional images, MDME sequence-derived synthetic MRI demonstrated an equal/greater signal-to-noise ratio and contrast-to-noise ratio (CNR) in all age groups. Specifically, for participants aged ≤2 years, synthetic T2-fluid-attenuated inversion recovery imaging showed a significantly higher cerebellum gray/white matter CNR (P < 0.05). In the qualitative and artifact analyses, except for the superior sagittal sinus and cranial nerves, synthetic MRI showed good imaging quality (≥3 points) in all brain structures. On synthetic T1-weighted imaging, high signal intensity within the superior sagittal sinus was found in most of our participants (107/118, 90.7%). No difference was observed between synthetic and conventional MRI in diagnosing the lesions.
Conclusion:
MDME sequence-derived synthetic MRI showed similar image quality and diagnostic performance with a shorter acquisition time than conventional MRI. However, the high signal intensity within the superior sagittal sinus on synthetic T1-weighted images requires consideration.
More Related Videos
12:50Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014
11:03High-resolution In Vivo Manual Segmentation Protocol for Human Hippocampal Subfields Using 3T Magnetic Resonance Imaging
Published on: November 10, 2015
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...