Related Experiment Video
Updated: Aug 10, 2025

Abbiategrasso Brain Bank Protocol for Collecting, Processing and Characterizing Aging Brains
Published on: June 3, 2020
Validation of SmartVA using conventional autopsy: A study of adult deaths in Brazil
John D Hart1, Paulo Afonso de André2, Carmen Diva Saldiva de André3
1Melbourne School of Population and Global Health, The University of Melbourne, Carlton, Victoria, Australia.
Background:
Accurate cause of death data are essential to guide health policy. However, mortality surveillance is limited in many low-income countries. In such settings, verbal autopsy (VA) is increasingly used to provide population-level cause of death data. VAs are now widely interpreted using the automated algorithms SmartVA and InterVA. Here we use conventional autopsy as the gold standard to validate SmartVA methodology.
Methods:
This study included adult deaths from natural causes in São Paulo and Recife for which conventional autopsy was indicated. VA was conducted with a relative of the deceased using an amended version of the SmartVA instrument to suit the local context. Causes of death from VA were produced using the SmartVA-Analyze program. Physician coded verbal autopsy (PCVA), conducted on the same questionnaires, and Global Burden of Disease Study data were used as additional comparators. Cause of death data were grouped into 10 broad causes for the validation due to the real-world utility of VA lying in identifying broad population cause of death patterns.
Findings:
The study included 2,060 deaths in São Paulo and 1,079 in Recife. The cause specific mortality fractions (CSMFs) estimated using SmartVA were broadly similar to conventional autopsy for: cardiovascular diseases (46.8% vs 54.0%, respectively), cancers (10.6% vs 11.4%), infections (7.0% vs 10.4%) and chronic respiratory disease (4.1% vs 3.7%), causes accounting for 76.1% of the autopsy dataset. The SmartVA CSMF estimates were lower than autopsy for "Other NCDs" (7.8% vs 14.6%) and higher for diabetes (13.0% vs 6.6%). CSMF accuracy of SmartVA compared to autopsy was 84.5%. CSMF accuracy for PCVA was 93.0%.
Interpretation:
The results suggest that SmartVA can, with reasonable accuracy, predict the broad cause of death groups important to assess a population's epidemiological transition. VA remains a useful tool for understanding causes of death where medical certification is not possible.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Assessment of blood pressure in brachial artery(two-step method)
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

