Related Experiment Video
Updated: Aug 10, 2025

04:19
Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
528
C2 Screw fixation techniques in atlantoaxial instability: A technical review
Deepak Kumar Singh1, Diwakar Shankar1, Neha Singh2
1Department of Neurosurgery, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
Journal of Craniovertebral Junction & Spine
|February 13, 2023
Summary
Atlantoaxial instability (AAI) treatment involves C1-C2 fusion. This review details common C2 screw fixation techniques, analyzing their technical and biomechanical aspects for surgical success.
Area of Science:
- Neurosurgery
- Orthopedic Surgery
- Spinal Fusion Techniques
Background:
- Atlantoaxial instability (AAI) presents significant surgical challenges due to its anatomical location near critical neurovascular structures.
- C1-C2 fusion is a well-established surgical standard for managing AAI.
- Optimal C2 screw fixation is crucial for the success of C1-C2 fusion in AAI.
Purpose of the Study:
- To provide a comprehensive overview of current C2 screw fixation techniques used in AAI surgery.
- To analyze the technical nuances and biomechanical properties of each described C2 screw fixation method.
- To enhance understanding of surgical options for C1-C2 fusion in AAI.
Main Methods:
- Review of common C2 screw fixation techniques: C2 pedicle, C2 pars, C2 translaminar, C2 subfacetal, C2-C3 transfacetal, and C2 inferior facet screw.
- Detailed discussion of the technical aspects and surgical considerations for each method.
- Analysis of the biomechanical principles underlying the stability provided by each fixation technique.
Main Results:
- Identification and description of six primary C2 screw fixation techniques for AAI.
- Elucidation of the specific anatomical landmarks, screw trajectories, and potential risks associated with each technique.
- Comparative insights into the biomechanical advantages and limitations of different C2 fixation methods.
Conclusions:
- A thorough understanding of various C2 screw fixation techniques is essential for neurosurgeons and orthopedic spine surgeons managing AAI.
- Each technique offers distinct advantages and disadvantages regarding technical feasibility, biomechanical stability, and potential complications.
- This review serves as a guide to selecting the most appropriate C2 fixation strategy based on individual patient anatomy and surgical goals.

