Related Experiment Video
Updated: Aug 10, 2025

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Co-linear common-path shearography with a zero-approaching shear amount and separate control of the spatial carrier
Abstract:
A co-linear common-path shearography is proposed with spatial phase shift for single-shot phase measurement. The co-linear common-path configuration brings an enhanced robustness and stability of the measuring system, because the two laterally sheared interfering object waves propagate essentially along the same path, which cancels out the disturbance and noise in surroundings. Two functional features, which break through the limitations in conventional co-linear common-path shearography, are proposed and implemented, namely the zero-approaching shear amount and the separate control of the spatial carrier. Seldom shearography configured by co-linear common-path structure possesses with these two features, because the linearly aligned optics restricts the control parameters in regards to the shear amount and the spatial carrier. In the proposed scheme, an intermediate real image plane is created in the linearly aligned light path to address the issue of zero-approaching shear amount. A 4-f imaging system is embedded with an aperture in between to implement a separate control of the spatial carrier. The zero-approaching shear amount provides the sufficiently small shear to make sure the strain or slope field of complex deformation is resolvable. Meanwhile, the separate control of the spatial carrier further guarantees a well-distributed spatial frequency spectrum when the required zero-approaching shear amount is configured.
More Related Videos
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
09:08Measuring Material Microstructure Under Flow Using 1-2 Plane Flow-Small Angle Neutron Scattering
Published on: February 6, 2014
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Shearing Strain
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
Shear on the Horizontal Face of a Beam Element