Related Experiment Video
Updated: Aug 9, 2025

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Identification and quantification of IEPOX in ambient aerosols, using electron and chemical ionization sources GC/MS
1Rural Environment Protection Engineering & Technology Center of Sichuan Province, College of Environmental Sciences, Sichuan Agricultural University, Chengdu 611130, China.
Abstract:
Isoprene is the most abundant non-methane hydrocarbon (NMHC) emitted by vegetation, and the precursor that makes the greatest contribution to secondary organic aerosols (SOA) in the troposphere. Atmospheric oxidation of isoprene produces a series of reactive intermediates, isoprene epoxydiols (IEPOX). The reactive uptake of IEPOX is the significant formation pathway of atmospheric SOA. In this work, four isomers of IEPOX were synthesized, derivatized by silylation reagents, and measured by gas chromatography/mass spectrometry (GC/MS). The electron-impact (EI) and methane chemical ionization (CI) sources mass spectra of trimethylsilyl ester (TMS) derivatives of IEPOX isomers were obtained and the fragmentation behaviors of the derivatives were examined. Moreover, the hydrogen nuclear magnetic resonance (H-NMR) spectra of IEPOX isomers were also obtained and the peak intensities in the H-NMR spectra were analyzed. Based on the standard spectra, IEPOX isomers were identified in ambient PM2.5 aerosols in the Gongga Mountain (China). The peak sequence of TMS derivatives of IEPOX isomers in GC/MS chromatogram was δ4-IEPOX, δ1-IEPOX, cis-β-IEPOX and trans-β-IEPOX. The isomers with the highest concentrations were δ1-IEPOX (threo- and erythro-). The mass ratios of IEPOX to 2-methyltetrols were 0.02-6.0 and the concentrations of IEPOX were 0.8-41.6 ng/m3 in the PM2.5 aerosols. The current study verified the core roles of IEPOX as active intermediates in photo oxidation of isoprene in ambient atmosphere.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
12:15Quantification of three DNA Lesions by Mass Spectrometry and Assessment of Their Levels in Tissues of Mice Exposed to Ambient Fine Particulate Matter
Published on: May 29, 2019
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Instrumentation