Related Experiment Video
Updated: Aug 9, 2025

Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
Monaural cardiopulmonary sound separation via complex-valued deep autoencoder and cyclostationarity
Chunjian Yang1, Nan Hu1, Dongyang Xu2
1School of Electronics and Information Engineering, Soochow University, Suzhou 215006, People's Republic of China.
Abstract:
Objective.Cardiopulmonary auscultation is promising to get smart due to the emerging of electronic stethoscopes. Cardiac and lung sounds often appear mixed at both time and frequency domain, hence deteriorating the auscultation quality and the further diagnosis performance. The conventional cardiopulmonary sound separation methods may be challenged by the diversity in cardiac/lung sounds. In this study, the data-driven feature learning advantage of deep autoencoder and the common quasi-cyclostationarity characteristic are exploited for monaural separation.Approach.Different from most of the existing separation methods that only handle the amplitude of short-time Fourier transform (STFT) spectrum, a complex-valued U-net (CUnet) with deep autoencoder structure, is built to fully exploit both the amplitude and phase information. As a common characteristic of cardiopulmonary sounds, quasi-cyclostationarity of cardiac sound is involved in the loss function for training.Main results. In experiments to separate cardiac/lung sounds for heart valve disorder auscultation, the averaged achieved signal distortion ratio (SDR), signal interference ratio (SIR), and signal artifact ratio (SAR) in cardiac sounds are 7.84 dB, 21.72 dB, and 8.06 dB, respectively. The detection accuracy of aortic stenosis can be raised from 92.21% to 97.90%.Significance. The proposed method can promote the cardiopulmonary sound separation performance, and may improve the detection accuracy for cardiopulmonary diseases.
More Related Videos
Related Concept Videos
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Sampling Continuous Time Signal
In the...
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...

