Myocardial blood flow evaluation with dynamic cadmium-zinc-telluride single-photon emission computed tomography:
Adriana D'Antonio1, Roberta Assante1, Emilia Zampella1
1Department of Advanced Biomedical Sciences, University of Naples Federico II, 80131 Naples, Italy.
Insights
Dynamic cadmium-zinc-telluride (CZT) SPECT offers a promising non-invasive method for assessing myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). However, standardizing protocols is crucial for widespread clinical adoption and accurate coronary artery disease evaluation.
Area of Science:
- Cardiovascular Imaging
- Nuclear Cardiology
- Medical Physics
Background:
- Non-invasive assessment of myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) is vital for evaluating coronary artery disease (CAD) severity and extent.
- Cardiac positron emission tomography-computed tomography (PET-CT) is the gold standard for coronary function assessment but is limited by cost and complexity.
- Cardiac-dedicated cadmium-zinc-telluride (CZT) cameras have reignited interest in quantitative myocardial perfusion imaging using single-photon emission computed tomography (SPECT).
Purpose of the Study:
- To review the current state of myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) evaluation using dynamic CZT-SPECT.
- To outline the challenges and areas for optimization in dynamic CZT-SPECT for clinical routine use.
- To compare the diagnostic performance of CZT-SPECT with PET-CT in detecting significant coronary artery stenosis.
Main Methods:
- Review of existing studies evaluating MBF and MPR using dynamic CZT-SPECT in patients with suspected or known CAD.
- Comparison of quantitative values obtained by CZT-SPECT and PET-CT.
- Analysis of factors influencing MBF/MPR quantitation, including camera types, protocols, tracers, and software.
Main Results:
- Numerous studies have assessed MPR and MBF using dynamic CZT-SPECT, showing good correlation with PET-CT in detecting significant coronary stenosis.
- Discrepancies in diagnostic cut-off values between CZT-SPECT and PET-CT highlight the need for standardization.
- Variability in cameras, protocols, tracers, and software packages complicates the comparison and clinical implementation of CZT-SPECT.
Conclusions:
- Dynamic CZT-SPECT shows potential for accurate MBF and MPR quantification, aiding in CAD assessment.
- Lack of standardized acquisition, reconstruction, and analysis protocols hinders inter-study comparability and clinical adoption.
- Addressing technical and methodological issues is essential to fully realize the clinical benefits of dynamic CZT-SPECT for myocardial perfusion imaging.
Abstract:
Myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) assessment with non-invasive techniques represent an important tool to evaluate both coronary artery disease severity and extent. Currently, cardiac positron emission tomography-computed tomography (PET-CT) is the "gold standard" for the assessment of coronary function and provides accurate estimations of baseline and hyperemic MBF and MFR. Nevertheless, due to the high cost and complexity, PET-CT is not widely used in clinical practice. The introduction of cardiac-dedicated cadmium-zinc-telluride (CZT) cameras has renewed researchers' interest on MBF quantitation by single-photon emission computed tomography (SPECT). Indeed, many studies evaluated MPR and MBF measurements by dynamic CZT-SPECT in different cohorts of patients with suspected or overt coronary artery disease. As well, many others have compared the values obtained by CZT-SPECT to the ones by PET-CT, showing good correlations in detecting significant stenosis, although with different and non-standardized cut-off values. Nevertheless, the lack of standardized protocol for acquisition, reconstruction and elaboration makes more difficult to compare different studies and to further assess the real advantages of MBF quantitation by dynamic CZT-SPECT in clinical routine. Many are the issues involved in the bright and dark sides of dynamic CZT-SPECT. They include different type of CZT cameras, different execution protocols, different tracers with different myocardial extraction fraction and distribution, different software packages with different tools and algorithms, often requiring manual post-processing elaboration. This review article provides a clear summary of the state of the art on MBF and MPR evaluation by dynamic CZT-SPECT and outlines the major issues to solve to optimize this technique.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
05:07Author Spotlight: Improved Localization and Monitoring of Coronary Flow Reserve Using Modified PLAX View in Mice
Published on: August 25, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT