Related Experiment Video
Updated: Aug 9, 2025

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Feasibility and reliability of comprehensive three-dimensional transoesophageal echocardiography screening process
Francesco Piroli1, Antonio Boccellino1, Giacomo Ingallina1
1Cardiovascular Imaging Unit, Cardio-Thoracic-Vascular Department, IRCCS San Raffaele Scientific Institute, via Olgettina 60, 20132 Milan, Italy.
Aims:
The procedural planning of transcatheter mitral valve replacement (TMVR) requires a specific imaging assessment to establish patient eligibility. Computed tomography (CT) is considered the reference method. In this setting, data regarding the role of transoesophageal echocardiography (TOE) are lacking. We evaluated the feasibility and reliability of a comprehensive 3D-TOE screening in TMVR candidates.
Methods And Results:
We performed a retrospective observational study including 72 consecutive patients who underwent a pre-procedural CT and 3D-TOE for TMVR evaluation. The measurements of mitral annulus (MA), length of anterior mitral leaflet (AML), native left ventricular outflow tract (LVOT), and predicted neo-LVOT acquired with CT and 3D-TOE were compared using a novel semi-automated software for post processing analysis (3 mensio Structural Heart 10.1-3mSH, Pie Medical Imaging, Bilthoven, Netherlands). The final suitability decision was given by the valve manufacturer based on CT measurements and clinical conditions. Among 72 patients screened, all patients had adequate image quality for 3D-TOE analysis. 3D-TOE and CT measurements for AML length (r = 0.97), MA area (r = 0.90), perimeter (r = 0.68), anteroposterior (r = 0.88), and posteromedial-anterolateral (r = 0.74) diameters were found highly correlated, as well as for native LVOT (r = 0.86) and predicted neo-LVOT areas (r = 0.96) (all P-values <0.0001). An almost perfect agreement between CT and 3DTOE was found in assessing the eligibility for TMVR implantation (Cohen kappa 0.83, P < 0.001).
Conclusion:
3D-TOE appraisements showed good correlations with CT measurements and high accuracy to predict TMVR screening success.