Related Experiment Video
Updated: Aug 9, 2025

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
IVUS determination of normal left main stem artery size and plaque burden, and correlation with body surface area in
Kirti Punamiya1, Tanya Jha1, Varun Punamiya2
1Cardiology, Breach Candy Hospital Trust, Mumbai, India.
Background:
There is a scarcity of data regarding the normal size of the left main stem coronary artery (LMS) in the Indian population; further data are needed to help determine the optimal device size during percutaneous coronary intervention (PCI).
Aims:
The aim of our study was to determine the normal size of the LMS and to calculate the mean plaque burden (PB) in the left main arteries which are angiographically normal or insignificantly diseased, using intravascular ultrasound (IVUS). We hoped to establish a correlation between LMS size and body surface area (BSA).
Methods:
We collected demographic and coronary artery data from 140 patients who underwent IVUS-guided PCI in the left anterior descending and circumflex arteries over a 2-year period from 2019 to 2020, where a pullback sequence of the LMS was available. The reference and luminal vessel diameters, the reference and luminal vessel areas and the mean plaque burden (PB) were obtained. Regression analysis was used to develop a correlation between BSA and LMS diameter.
Results:
The IVUS-determined mean reference diameter of the LMS was 5.53±0.63 mm and the mean luminal diameter was 4.62±0.65 mm. The mean reference vessel area was 24.79±5.5 mm2 and the luminal vessel area was 17.19±4.89 mm2. The mean PB was found to be 29.21% in patients with an angiographically normal left main and 32.29% in patients with angiographically insignificant left main stenosis. A linear correlation was noted between the left main reference and luminal vessel diameters; the correlation equations derived were 3.57+1.01 BSA and 2.95+0.87 BSA, respectively.
Conclusions:
The mean reference and luminal diameters of LMS in the Indian population are on par with the size of LMS in other ethnicities. The vessel compensates for up to 40% PB with vessel remodelling. Hence, a PB of 40% is a good landing zone for stent deployment.
More Related Videos
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Related Concept Videos
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System IV: CMRI
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Imaging Studies for Cardiovascular System V: CT