Background:
Esophageal button battery ingestion is a significant problem that can lead to significant complications such as tracheoesophageal fistula, esophageal perforation, and aortoesophageal fistula. Due to this, prompt recognition and treatment is integral in the care of these patients.
Methods:
Patients who presented to a single institution from August 2015 to April 2022 with esophageal button battery ingestion were included in this study. All esophageal button battery ingestion patients were included in a clinical algorithm for Critical Airway Response Team (CART) activation in October 2019. Time from diagnosis to treatment was compared for pre-CART clinical algorithm implementation to post-CART.
Results:
Data on pre-CART patients (n = 6) and post-CART patients (n = 7) was collected. Including esophageal button battery ingestions to CART activations shortened the time from chest x-ray to button battery removal from 73 ± 32 min to 35 ± 11 min (p < 0.05).
Conclusion:
These data highlight the importance of implementation of a clinical care algorithm to shorten the time from diagnosis to treatment in patients with esophageal button battery ingestion.
Level Of Evidence:
III.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...