Related Experiment Video
Updated: Aug 9, 2025

Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
Published on: September 6, 2017
Clinical Evaluation of a Wireless Device for Monitoring Vitals in Newborn Babies
Rajiv Aggarwal1, Vikneswaran Gunaseelan2, Delitia Manual3
1Department of Pediatrics, Narayana Hrudayalaya, Bangalore, Karnataka, India.
Objectives:
To evaluate the ability of the Nemocare Raksha (NR), an internet of things (IoT)-enabled device, to continuously monitor vitals for 6 h and its safety in newborns. The accuracy of the device was also compared with the readings from the standard device used in the pediatric ward.
Method:
Forty neonates (either gender) weighing ≥ 1.5 kg were included in the study. Heart rate, respiratory rate, body temperature, and oxygen saturation was measured using the NR and compared with standard care devices. Safety was assessed by monitoring for skin changes and local rise in temperature. The neonatal infant pain scale (NIPS) was used to assess pain and discomfort.
Result:
A total of 227 h of observations (5.67 h per baby) were obtained. No discomfort or device-related adverse events were noted during the study period. The mean difference between the NR and the standard monitoring was 0.66 (0.42 to 0.90) for temperature (°C); -6.57 (-8.66 to -4.47) for heart rate (bpm); 7.60 (6.52 to 8.68) for respiratory rate (breaths per minute); -0.79 (-1.10 to -0.48) for oxygen saturation (%). The level of agreement analyzed using the intraclass correlation coefficient (ICC) was good for heart rate [ICC 0.77 (0.72 to 0.82); p value < 0.001] and oxygen saturation [ICC 0.80 (0.75 to 0.84); p value < 0.001]; moderate for body temperature [ICC 0.54 (0.36 to 0.60); p value < 0.001] and poor for respiratory rate [ICC 0.30 (0.10 to 0.44); p value 0.002].
Conclusion:
The NR was able to seamlessly monitor vital parameters in neonates without any safety concern. The device showed a good level of agreement for heart rate and oxygen saturation among the four parameters measured.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Holter Monitor: 24-Hour Monitoring
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...