Related Experiment Video
Updated: Aug 9, 2025

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Estimating Crestal Thickness of Alveolar Bones on Intra-oral Ultrasonograms
Lawrence H Le1, Kim-Cuong T Nguyen2, Phuong-Thuy T Nguyen3
1Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada; Department of Physics, University of Alberta, Edmonton, Alberta, Canada; School of Dentistry, University of Alberta, Edmonton, Alberta, Canada.
Objective:
Alveolar crestal bone thickness and level provide important diagnostic and prognostic information for orthodontic treatment, periodontal disease management and dental implants. Ionizing radiation-free ultrasound has emerged as a promising clinical tool in imaging oral tissues. However, the ultrasound image is distorted when the wave speed of the tissue of interest is different from the mapping speed of the scanner and, therefore, the subsequent dimension measurements are not accurate. This study was aimed at deriving a correction factor that can be applied to the measurements to correct for discrepancy caused by speed variation.
Methods:
The factor is a function of the speed ratio and the acute angle that the segment of interest makes with the beam axis perpendicular to the transducer. The phantom and cadaver experiments were designed to validate the method.
Discussion:
The comparisons agree well with absolute errors not more than 4.9%. Dimension measurements on ultrasonographs can be properly corrected by applying the correction factor without recourse to the raw signals.
Conclusion:
The correction factor has reduced the measurement discrepancy on the acquired ultrasonographs for the tissue whose speed is different from the scanner's mapping speed.