Unexpected Performance Improvements of Nitrogen Dioxide and Ozone Sensors by Including Carbon Monoxide Sensor Signal
Md Hasibul Hasan1, Haofei Yu1, Cesunica Ivey2
1Department of Civil, Environmental and Construction Engineering, University of Central Florida, Orlando, Florida32816, United States.
Abstract:
Low-cost air quality (LCAQ) sensors are increasingly being used for community air quality monitoring. However, data collected by low-cost sensors contain significant noise, and proper calibration of these sensors remains a widely discussed, but not yet fully addressed, area of concern. In this study, several LCAQ sensors measuring nitrogen dioxide (NO2) and ozone (O3) were deployed in six cities in the United States (Atlanta, GA; New York City, NY; Sacramento, CA; Riverside, CA; Portland, OR; Phoenix, AZ) to evaluate the impacts of different climatic and geographical conditions on their performance and calibration. Three calibration methods were applied, including regression via linear and polynomial models and random forest methods. When signals from carbon monoxide (CO) sensors were included in the calibration models for NO2 and O3 sensors, model performance generally increased, with pronounced improvements in selected cities such as Riverside and New York City. Such improvements may be due to (1) temporal co-variation between concentrations of CO and NO2 and/or between CO and O3; (2) different performance levels of low-cost CO, NO2, and O3 sensors; and (3) different impacts of environmental conditions on sensor performance. The results showed an innovative approach for improving the calibration of NO2 and O3 sensors by including CO sensor signals into the calibration models. Community users of LCAQ sensors may be able to apply these findings further to enhance the data quality of their deployed NO2 and O3 monitors.
More Related Videos
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Turnover Number and Catalytic Efficiency
Chymotrypsin is a pancreatic enzyme that breaks down proteins during digestion....
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...