Compression of 99mTc Methylene Diphosphonate Bone Scan Images using Discrete Cosine Transformation
Anil Kumar Pandey1, Priya Yadav1, Jagrati Chaudhary1
1Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Summary
The optimal threshold for compressing technetium-99m-labeled methylene diphosphonate (99mTc-MDP) bone scan images using discrete cosine transformation (DCT) is 10. This method achieved an average compression factor of 13.03, with most compressed images deemed acceptable by physicians.
Area of Science:
- Medical Imaging
- Digital Signal Processing
- Nuclear Medicine
Background:
- Bone scan imaging, particularly with 99mTc-MDP, is crucial for diagnosing various bone pathologies.
- Efficient storage and transmission of medical images are essential in modern healthcare systems.
- Discrete Cosine Transformation (DCT) is a widely used technique for image compression.
Purpose of the Study:
- To determine the optimal threshold value for compressing 99mTc-MDP bone scan images using DCT.
- To evaluate the effectiveness of DCT-based compression in maintaining diagnostic quality.
- To quantify the compression ratio achievable with the proposed method.
Main Methods:
- DCT was applied to 51 99mTc-MDP bone scan images.
- The logarithmic values of DCT coefficients were analyzed to identify an appropriate threshold.
- Inverse DCT was used to reconstruct compressed images after applying a threshold of 10.
- Compression factor was calculated based on the ratio of non-zero DCT coefficients before and after thresholding.
- Nuclear medicine physicians assessed the diagnostic acceptability of compressed images based on specific criteria.
Main Results:
- A threshold value of 10 was determined to be optimal for compression.
- Forty-four out of 51 compressed images (86.3%) were deemed acceptable by nuclear medicine physicians.
- The average compression factor achieved was 13.03, representing a significant reduction in data size.
- Compressed images exhibited reduced noise compared to the original images.
Conclusions:
- The optimal threshold for compressing 99mTc-MDP bone scan images using DCT is 10.
- DCT-based compression with a threshold of 10 provides an average compression factor of 13.03 (92.30%) while maintaining diagnostic acceptability.
- This technique offers a viable method for reducing the storage and transmission burden of bone scan images.