Validation of Sequential ROX-Index Score Beyond 12 Hours in Predicting Treatment Failure and Mortality in COVID-19
Dimitris Basoulis1,2, Pantelis Avramopoulos2, Maria Aggelara3
1Infectious Diseases and COVID-19 Unit, Athens, Greece.
Background:
High-flow nasal cannula (HFNC) is an oxygen delivery method shown to reduce the risk of intubation and mortality in patients with type 1 respiratory failure. The ROX-index score can predict HFNC failure. This study aims to evaluate sequential ROX-index assessments as predictors of HFNC failure and mortality.
Methods:
Prospective observational single-center study including all adult patients with positive SARS-CoV-2 PCR placed under HFNC from 1st November 2020 to 31st May 2021, and patients with hemodynamic instability or unable to tolerate HFNC were excluded. The primary endpoint was successful HFNC de-escalation.
Results:
In univariate analysis, HFNC de-escalation was associated with younger age (59.2 ± 14 vs. 67.7 ± 10.5 and p < 0.001), lower levels of serum lactate (1.1 vs. 1.5 and p=0.013), and higher ROX-index at 12 hrs (5.09 vs. 4.13 and p < 0.001). ROC curve analysis of ROX-index at 12 hrs yielded a c-statistic of 71.2% (95% CI 61.6-80.9 and p < 0.001). ROX-index at 12 hrs and age retained significance in multivariate analysis. Using an optimal cutoff point of 4.43, we calculated a sensitivity of 64.5% and specificity of 69.6%. In univariate survival analysis, older age (68.8 ± 9.7 vs. 58.9 ± 13.9 and p < 0.001), greater creatinine values (0.96 vs. 0.84 and p=0.022), greater SOFA score (p=0.039), and a lower 12 hrs ROX-index (4.22 vs. 4.95 and p=0.02) were associated with hospital mortality. The SOFA score and age retained significance in multivariate survival analysis.
Conclusion:
ROX-index is proven to be a valuable and easy-to-use tool for clinicians in the assessment of COVID-19 patients under HFNC.
Related Concept Videos
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...