Related Experiment Video
Updated: Aug 9, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Automatic daily remote monitoring in heart failure patients implanted with a cardiac resynchronisation
Peter Ezer1, Nelli Farkas2, István Szokodi1,3
1Heart Institute, University of Pécs, Medical School, Foreign Medical Sciences, Hungary.
Introduction:
The impact of remote monitoring (RM) on clinical outcomes in heart failure (HF) patients with cardiac resynchronisation therapy-defibrillator (CRT-D) implantation is controversial. This study sought to evaluate the performance of an RM follow-up protocol using modified criteria of the PARTNERS HF trial in comparison with a conventional follow-up scheme.
Material And Methods:
We compared cardiovascular (CV) mortality (primary endpoint) and hospitalisation events for decompensated HF, and the number of ambulatory in-office visits (secondary endpoint) in CRT-D implanted patients with automatic RM utilising daily transmissions (RM group, n = 45) and conventional follow-up (CFU group, n = 43) in a single-centre observational study.
Results:
After a median follow-up of 25 months, a significant advantage was seen in the RM group in terms of CV mortality (1 vs. 6 death event, p = 0.04), although RM follow-up was not an independent predictor for CV mortality (HR = 0.882; 95% CI: 0.25-3.09; p = 0.845). Patient CV mortality was independently influenced by hospitalisation events for decompensated HF (HR = 3.24; 95% CI: 8-84; p = 0.022) during follow-up. We observed significantly fewer hospitalisation events for decompensated HF (8 vs. 29 events, p = 0.046) in the RM group. Furthermore, a decreased number of total (161 vs. 263, p < 0.01) and unnecessary ambulatory in-office visits (6 vs. 19, p = 0.012) were seen in the RM group as compared to the CFU group.
Conclusions:
Follow-up of CRT-D patients using automatic RM with daily transmissions based on modified PARTNERS HF criteria enabled more effective ambulatory interventions leading indirectly to improved CV survival. Moreover, RM directly decreased the number of HF hospitalizations and ambulatory follow-up burden compared to CRT-D patients with conventional follow-up.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure VI: Adjunct Therapies
Dysrhythmias VII: Nursing Management of Dysrhythmias