Related Experiment Video
Updated: Aug 9, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Optimal radiotherapy modality sparing for cardiac valves in left-sided breast cancer
Ningning Zhang1, Xianfeng Liu2, Dan Tao2,3
1Department of Breast Cancer Center, Chongqing University Cancer Hospital, Chongqing, China.
Background:
The cardiotoxicity caused by radiotherapy is a critical problem in the treatment of patients with breast cancer. The appropriate radiotherapy modality sparing for cardiac valves in left-sided breast cancer has not been well defined. The aim of this study was thus to compare the dosimetric differences in heart and cardiac valves of 3-dimensional conformal radiotherapy (3D-CRT), fixed-field intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) to find the optimal radiotherapy modality sparing for cardiac valves in patients with left breast cancer.
Methods:
From January 5, 2021, to March 15, 2021, 21 patients with left-sided breast cancer postmastectomy were included in this study, and 3 different plans for adjuvant radiation were created using 3D-CRT, IMRT, and VMAT for each patient. All patients received 50 Gy in 25 fractions. The mean dose (Dmean) of the heart; percentage volume of the heart receiving ≥5 Gy (V5), ≥30 Gy (V30), and ≥40 Gy (V40); and the Dmean and the near-maximum dose (D0.03cc) of cardiac valves were extracted from dose-volume histograms (DVHs) and compared. The correlations in dosimetric factors between cardiac valves and the whole heart were analyzed.
Results:
IMRT significantly decreased the values of V5, V30, V40, and Dmean in the whole heart compared to 3D-CRT and VMAT (P<0.001). Among the 3 different plans, IMRT had the lowest radiation dose to the Dmean and the D0.03cc of the aortic valve (1.27 Gy/1.75 Gy), pulmonary valve (3.44 Gy/6.89 Gy), tricuspid valve (1.02 Gy/1.14 Gy), and mitral valve (0.93 Gy/1.00 Gy). Pearson correlation analysis found that local parameters (Dmean and D0.03cc) within valves were strongly correlated to the global parameters (V5, V30, V40, and Dmean) of the heart.
Conclusions:
This study revealed that IMRT showed the lowest cardiac valves dose compared with 3D-CRT and VMAT in left-sided breast cancer radiotherapy. IMRT might be the optimal modality sparing for cardiac valves in this group of patients. Further studies need to be carried out in order to validate the protective role of IMRT on the cardiac valves.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Mitral Stenosis III: Medical Management
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...