Related Experiment Video
Updated: Aug 9, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Elevations in End-Tidal CO 2 With CO 2 Use During Pediatric Endoscopy With Airway Protection: Is This Physiologically
Chinenye R Dike1,2, Andrew Huang Pacheco1, Elizabeth Lyden3
1From the Division of Pediatric Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, University of Nebraska Medical Center and Children's Hospital & Medical Center, Omaha, NE.
Background:
Inflation of the gastrointestinal lumen is vital for proper visualization during endoscopy. Air, insufflated via the endoscope, is gradually being replaced with carbon dioxide (CO 2 ) in many centers, with the intention of minimizing post-procedural discomfort due to retained gas. Recent studies suggest that the use of CO 2 during pediatric esophagogastroduodenoscopy (EGD) with an unprotected airway is associated with transient elevations in exhaled CO 2 (end-tidal CO 2 , EtCO 2 ), raising safety concerns. One possible explanation for these events is eructation of insufflation gas from the stomach.
Objectives:
To distinguish eructated versus absorbed CO 2 by sampling EtCO 2 from a protected airway with either laryngeal mask airway (LMA) or endotracheal tube (ETT), and to observe for changes in minute ventilation (MV) to exclude hypoventilation events.
Methods:
Double-blinded, randomized clinical trial of CO 2 versus air insufflation for EGD with airway protection by either LMA or ETT. Tidal volume, respiratory rate, MV, and EtCO 2 were automatically recorded every minute. Cohort demographics were described with descriptive characteristics. Variables including the percent of children with peak, transient EtCO 2 ≥ 60 mmHg were compared between groups.
Results:
One hundred ninety-five patients were enrolled for 200 procedures. Transient elevations in EtCO 2 of ≥60 mmHg were more common in the CO 2 group, compared to the air group (16% vs 5%, P = 0.02), but were mostly observed with LMA and less with ETT. Post-procedure pain was not different between groups, but flatulence was reported more with air insufflation ( P = 0.004).
Conclusion:
Transient elevations in EtCO 2 occur more often with CO 2 than with air insufflation during pediatric EGD despite protecting the airway with an LMA or, to a lesser degree, with ETT. These elevations were not associated with changes in MV. Although no adverse clinical effects from CO 2 absorption were observed, these findings suggest that caution should be exercised when considering the use of CO 2 insufflation, especially since the observed benefits of using this gas were minimal.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Hyperpnea and Hyperventilation
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated....
Acute Respiratory Failure-III