Quantitative photoacoustic tomography with light fluence compensation based on radiance Monte Carlo model
Sun Zheng1,2, Hou Yingsa1, Sun Meichen1
1Department of Electronic and Communication Engineering, North China Electric Power University, Baoding 071003, Hebei, People's Republic of China.
Abstract:
Objective. Photoacoustic tomography (PAT) is a rapidly evolving imaging modality that provides images with high contrast and spatial resolution showing the optical properties of biological tissues. The photoacoustic pressure is proportional to the product of the optical absorption coefficient and the local light fluence. The essential challenge in reconstructing quantitative images representing spatially varying absorption coefficients is the unknown light fluence. In addition, optical attenuation induces spatial variations in the light fluence, and the heterogeneity of the fluence determines the limits of reconstruction quality and depth.Approach.In this work, a reconstruction enhancement scheme is proposed to compensate for the variation in the light fluence in the absorption coefficient recovery. The inverse problem of the radiance Monte Carlo model describing light transport through the tissue is solved by using an alternating optimization strategy. In the iteration, the absorption coefficients and photon weights are alternately updated.Main results.The method provides highly accurate quantitative images of absorption coefficients in simulations, phantoms, andin vivostudies. The results show that the method has great potential for improving the accuracy of absorption coefficient recovery compared to conventional reconstruction methods that ignore light fluence variations. Comparison with state-of-the-art fluence compensation methods shows significant improvements in root mean square error, normalized mean square absolute distance, and structural similarity metrics.Significance.This method achieves high precision quantitative imaging by compensating for nonuniform light fluence without increasing the complexity and operation of the imaging system.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography