Related Experiment Video
Updated: Aug 9, 2025

State of the Art Cranial Ultrasound Imaging in Neonates
Published on: February 2, 2015
[Creation of Protective Equipment for Portable Radiography in Neonatal Intensive Care Unit]
Mei Takeya1, Rei Takagi1, Satoru Ishida1
1Department of Central Radiology, Toho University Sakura Medical Center.
Portable imaging in the NICU requires the assistance of a nurse, and the nurse is in close proximity to the X-ray tube, In all, 64 percent of our nurses thought that additional protective equipment was needed. Therefore, a radiation protection device was created and its usefulness was verified. A protective equipment of 0.13 mmPb with a width of 38 cm and a length of 70 cm was made and hung from the mono-tank X-ray unit of the mobile X-ray unit. The position of the nurse was set at 30 cm outward from the center of the irradiation field, and the protective effect was measured at three points: (a) the patient's height, (b) 30 cm above the patient, and (c) 60 cm above the patient. For the imaging conditions, a 2-liter plastic bottle filled with water was placed in the incubator, and measurements were taken with an SID of 100 cm, irradiated field of 20.3 cm×25.4 cm, tube voltage of 58 kV, and tube current-time product of 10 mAs, which was converted to the actual imaging condition of 1 mAs. Based on the results obtained, a questionnaire survey was conducted on nurses' thoughts for the protective equipment created for them. Only 3% reduction in height of (a) where no protective equipment is reached but (b) 50% and (c) 92%, respectively. In all, 82 percent of the nurses had a favorable impression of the new protective equipment. It is expected that the protective equipment designed to control lens dose and reduce anxiety of nurses will be useful.
Portable imaging in the NICU requires the assistance of a nurse, and the nurse is in close proximity to the X-ray tube, In all, 64 percent of our nurses thought that additional protective equipment was needed. Therefore, a radiation protection device was created and its usefulness was verified. A protective equipment of 0.13 mmPb with a width of 38 cm and a length of 70 cm was made and hung from the mono-tank X-ray unit of the mobile X-ray unit. The position of the nurse was set at 30 cm outward from the center of the irradiation field, and the protective effect was measured at three points: (a) the patient's height, (b) 30 cm above the patient, and (c) 60 cm above the patient. For the imaging conditions, a 2-liter plastic bottle filled with water was placed in the incubator, and measurements were taken with an SID of 100 cm, irradiated field of 20.3 cm×25.4 cm, tube voltage of 58 kV, and tube current-time product of 10 mAs, which was converted to the actual imaging condition of 1 mAs. Based on the results obtained, a questionnaire survey was conducted on nurses' thoughts for the protective equipment created for them. Only 3% reduction in height of (a) where no protective equipment is reached but (b) 50% and (c) 92%, respectively. In all, 82 percent of the nurses had a favorable impression of the new protective equipment. It is expected that the protective equipment designed to control lens dose and reduce anxiety of nurses will be useful.
More Related Videos
Related Concept Videos
Personal Protective Equipment
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Radiological Investigation I: X-ray and CT
PPE Use in Healthcare Settings I: Donning
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
X-ray Imaging

