Mixed multiscale BM4D for three-dimensional optical coherence tomography denoising
Ashkan Abbasi1, Amirhassan Monadjemi2, Leyuan Fang3
1Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, USA.
Abstract:
A multiscale extension for the well-known block matching and 4D filtering (BM4D) method is proposed by analyzing and extending the wavelet subbands denoising method in such a way that the proposed method avoids directly denoising detail subbands, which considerably simplifies the computations and makes the multiscale processing feasible in 3D. To this end, we first derive the multiscale construction method in 2D and propose multiscale extensions for three 2D natural image denoising methods. Then, the derivation is extended to 3D by proposing mixed multiscale BM4D (mmBM4D) for optical coherence tomography (OCT) image denoising. We tested mmBM4D on three public OCT datasets captured by various imaging devices. The experiments revealed that mmBM4D significantly outperforms its original counterpart and performs on par with the state-of-the-art OCT denoising methods. In terms of peak-signal-to-noise-ratio (PSNR), mmBM4D surpasses the original BM4D by more than 0.68 decibels over the first dataset. In the second and third datasets, significant improvements in the mean to standard deviation ratio, contrast to noise ratio, and equivalent number of looks were achieved. Furthermore, on the downstream task of retinal layer segmentation, the layer quality preservation of the compared OCT denoising methods is evaluated.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Three-Dimensional Microscopy in Microbiology
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...