Preanalytical Errors in a Hematology Laboratory: An Experience from a Tertiary Care Center
Mohammad Shahid Iqbal1, Aisha Tabassum1, Ahmad Fawzi Arbaeen2
1Department of Laboratory Medicine, College of Applied Medical Sciences, Umm al Qura University, Makkah 21955, Saudi Arabia.
Background:
Laboratory errors arise at any stage of testing. Detecting these inaccuracies before results are revealed might delay diagnosis and treatment, causing patient distress. Here, we studied the preanalytical errors in a hematology laboratory.
Methods:
This one-year retrospective analysis was conducted at the laboratory of a tertiary care hospital and included information on blood samples that were taken for hematology tests from both outpatients and inpatients. Laboratory records included sample collection and rejection information. The type and frequency of preanalytical errors were expressed as a proportion of total errors and sample number. Microsoft Excel was utilized to enter data. The results were presented in the form of frequency tables.
Results:
This research included 67,892 hematology samples. For preanalytical errors, 886 samples (1.3%) were discarded. The most common preanalytical error was insufficient sample (54.17%), and the least common was an empty/damaged tube (0.4%). Erroneous samples in the emergency department were mostly insufficient and clotted, whereas pediatric sample errors were caused by insufficient and diluted samples.
Conclusion:
Inadequate samples and clotted samples account for the vast majority of preanalytical factors. Insufficiency and dilutional errors were most frequent from pediatric patients. Adherence to best laboratory practices can drastically cut down on preanalytical errors.
More Related Videos
05:35Author Spotlight: Developing a Point-of-Care Hemoglobin Estimation Method for Anemia Management
Published on: January 19, 2024
14:45Enumeration of Major Peripheral Blood Leukocyte Populations for Multicenter Clinical Trials Using a Whole Blood Phenotyping Assay
Published on: September 16, 2012
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...