Research on Structurally Constrained KELM Fault-Diagnosis Model Based on Frequency-Domain Fuzzy Entropy

Xiaosu Feng1, Guanghui Zhang1, Xuyi Yuan1

  • 1Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China.

Related Concept Videos

Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
112
Discrete Fourier Transform01:15

Discrete Fourier Transform

The Discrete Fourier Transform (DFT) is a fundamental tool in signal processing, extending the discrete-time Fourier transform by evaluating discrete signals at uniformly spaced frequency intervals. This transformation converts a finite sequence of time-domain samples into frequency components, each representing complex sinusoids ordered by frequency. The DFT translates these sequences into the frequency domain, effectively indicating the magnitude and phase of each frequency component present...
357
Expected Frequencies in Goodness-of-Fit Tests01:19

Expected Frequencies in Goodness-of-Fit Tests

A goodness-of-fit test is conducted to determine whether the observed frequency values are statistically similar to the frequencies expected for the dataset. Suppose the expected frequencies for a dataset are equal such as when predicting the frequency of any number appearing when casting a die. In that case, the expected frequency is the ratio of the total number of observations (n)  to the number of categories (k).
2.6K
Dynamic Modulus of Elasticity of Concrete01:16

Dynamic Modulus of Elasticity of Concrete

The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
451
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
126
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
302