Polyacrylic Acid/Polyaniline-Coated Multimode Interferometer for Ammonia Detection
Ning Wang1, Chao Zhao1, Gang Long1
1National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China.
Abstract:
A coaxial optical fiber interferometer (COFI) is proposed here for ammonia sensing, which comprises two light-carrying single-mode fibers (SMF) fused to a section of no-core fiber (NCF), thus forming an optical interferometer. The outer surface of the COFI is coated with a layer of polyacrylic acid (PAA)/polyaniline (PAni) film. The refractive index (RI) of the sensitive layer varies when PAA/PAni interacts with ammonia, which leads to the resonance wavelength shift. The surface morphology and structure of the PAA/PAni composites were characterized by using a scanning electron microscope (SEM) and Fourier-transform infrared (FTIR) spectroscopy. When the sensor was exposed to an ammonia atmosphere of different concentrations at room temperature, the sensing performance of the PAA/PAni composite film was superior to that of a sensitive film formed by single-component PAA or PAni. According to the experimental results, the composite film formed by 5 wt% PAA mixed with 2 wt% PAni shows better performance when used for ammonia sensing. A maximum sensitivity of 9.8 pm/ppm was obtained under the ammonia concentration of 50 ppm. In addition, the sensor shows good performance in response time (100 s) and recovery time (180 s) and has good stability and selectivity. The proposed optical fiber ammonia sensor is adapted to monitor leakage in its production, storage, transportation, and application.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Gas Chromatography: Types of Detectors-II
NMR Spectroscopy Of Amines
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....