Related Experiment Video
Updated: Aug 9, 2025

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Study on the Single Sheet Measurement Method for AC Magnetic Measurement on Grain-Oriented Electrical Steel
Qian Xiang1,2, Lin Cheng1, Kaiming Wu1
1The State Key Laboratory of Refractories and Metallurgy, Hubei Province Key Laboratory of Systems Science on Metallurgical Processing, International Research Institute for Steel Technology, Collaborative Center on Advanced Steels, Wuhan University of Science and Technology, Wuhan 430081, China.
Abstract:
To quickly and accurately measure the AC magnetic properties of grain-oriented electrical steel by means of the existing measuring system designed for the magnetizing current method (MC), specifically the SST (92) single sheet method, in this work, the H-coil (HC) measuring system, which directly senses the magnetic field strength of the tested sample, was designed to measure the AC magnetic properties of the grain-oriented electrical steel. The assumed effective magnetic path length introduced in the MC method was corrected by comparing the measurement results obtained by means of HC and MC methods. The results found that specific total loss measured by the HC method was significantly lower than that measured by the classical magnetizing current (MC) method. Taking the HC method as the reference, the influencing factors of the effective magnetic path length was studied. It was found that the actual effective magnetic path length depends on the investigated sample characteristics, the measurement conditions, as well as yoke characteristics. The actual effective magnetic path length introduced in the MC method is examined to be more than 450 mm, fluctuating around 468 mm.
Related Concept Videos
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Measurements of Strain
Distance Measurements by Taping
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Magnetic Force On Current-Carrying Wires: Example